The AC330 Three-Phase Power Analyzer delivers reliable, professional-grade performance. It achieves 0.1 % voltage and current accuracy, with measurement bandwidth from 0.5 Hz to 100 kHz. The maximum voltage is 1000 Vrms, and the maximum current options include 50 A, 20 A, 10 A, 5 A, 2 A, and 1 A. Mixed-range configuration is supported, and external sensors are available as an option. It is widely used to measure parameters such as voltage, current, power, frequency, and harmonics of single-phase electrical equipment.
| Model | Voltage | Current | Accuracy | Interface | Size | Inquiry | |
|---|---|---|---|---|---|---|---|
| AC330 | 1000Vrms | 50A/20A/10A/5A/2A/1A | ±0.1% | RS-232 / Digital I/O / RS-485 / LAN Port | 3U | ||
| No models match the selected filters | |||||||
*Specifications for the product series are subject to change without notice.
• Large touch-screen: 800 × 480 high-brightness, high-resolution touch-screen for simple, intuitive operation
• High Accuracy: High-speed DSP processor and 16-bit high-speed, high-precision AD converter; basic accuracy up to 0.1 %; minimum data update cycle of 100 ms
• Wide power measurement range: Single channel measurable current up to 50 A (20 A, 10 A, 5 A, 2 A, 1 A variants optional; mixed‑range configuration supported). Minimum power resolution of 0.1 mW, covering both standby power consumption and rated power measurement requirements
• Wide bandwidth: supports both AC and DC signals; power measurement bandwidth DC, 0.5 Hz ~ 100 kHz. Suitable for power measurement of loads with standard and non-standard sinusoidal waveforms
• Three‑phase harmonics: Simultaneous harmonic analysis for all three phases, up to 50th‑order harmonic measurement and distortion‑analysis; visual display of individual‑order harmonic content and total harmonic content
• Three-Phase Frequency: Simultaneous frequency measurement on all three phases
• Line filtering: built‑in 500 Hz and 5.5 kHz low‑pass filters for measuring fundamental values of PWM waveforms and suppressing high‑frequency current interference from switching power supplies
• Sensors: ratio setting function, compatible with conventional I-I and V-V voltage/current transformers; supports I-V current sensors with a BNC interface, with maximum input voltage of 10 V. High-current sensors are available as an option
• Efficiency Calculation: Simultaneously measures input and output energy consumption of the DUT and calculates its efficiency
• Energy Accumulation: Supports independent accumulation of forward, reverse, and total energy for billing and net‑metering applications
• Threshold alarm: Independent threshold and limit‑value configuration for voltage, current, power, power factor on each channel; automatic upper/lower‑limit detection with alarm triggering
• Bilingual Interface: Switchable Chinese/English user interface
Channel Configuration
The three‑phase power analyzer supports multiple wiring configurations, including 1P2W, 1P3W, 3P3W, 3V3A, and 3P4W. Users can configure multi-channel modes according to application requirements to measure voltage, current, power, efficiency, and other parameters of various loads.
Wiring Configuration | Channel 1 | Channel 2 | Channel 3 |
1P2W (Single-phase Two-wire) | 1P2W | 1P2W | 1P2W |
1P3W(Single-phase Three-wire) | 1P3W | ||
3P3W (Three-phase Three-wire) | 3P3W | ||
3V3A (Three-phase Three-wire) | 3V3A | ||
3P4W(Three-phase Four-wire) | 3P4W | ||
Main Functions
Single‑channel measurement
| Peak detection
|
Energy measurement
| Efficiency measurement
|
Three‑phase measurement
| Harmonic analysis
|
Model | AC330 | |
Product Name | Three-Phase Power Analyzer | |
Measurement Channels | 3 | |
Wiring Configuration | 1P2W (Single-phase 2-wire), 1P3W (Single-phase 3-wire), 3P3W (3-phase 3-wire, 2 voltage, 2 current), 3P3W (3V3A) (3-phase 3-wire, 3 voltage, 3 current), 3P4W (3-phase 4-wire) | |
Measurement Parameters | Voltage (U), Current (I), Active Power (P), Reactive Power (Q), Apparent Power (S), Power Factor (PF), Voltage Frequency (fU), Current Frequency (fI), Phase Angle (Φ), Efficiency (η), Total Energy (Wh), Forward Energy (Wh+), Reverse Energy (Wh–), Current Integration (Ah), 50th Harmonic Analysis (HDF), Voltage and Current Total Harmonic Distortion (THD), Peak Voltage (Upk), Peak Current (Ipk), Voltage Crest Factor (CfU), Current Crest Factor (CfI), DC Voltage (Udc), DC Current (Idc), Average rectified value (Umn/Imn/Urmn/Irmn),Three-phase Parameters (Σ) | |
Input Impedance | Voltage: approx. 2 MΩ | |
Current Direct Input: Approx. 2.5 mΩ (50 A range); Current sensor input: approx. 100 kΩ | ||
A/D Sampling Rate | Approx. 100 kS/s | |
Full-Scale Crest Factor | 3 | |
Voltage Rated Range | 15/30/60/100/150/300/600/1000*[V] | |
(Direct Input) | *Full-scale crest factor for 1000 V range is 1.5 | |
Rated Current Range | 50 A model: 500 m / 1 / 2 / 5 / 10 / 20 / 40 / 50* [A] | |
Optional: | ||
20 A model: 100m/200m/500m/1/2/5/10/20* [A] | ||
10 A model: 50m/100m/200m/500m/1/2/5/10* [A] | ||
5 A model: 20m/50m/100m/200m/500m/1/2/5* [A] | ||
2 A model: 10m/20m/50m/100m/200m/500m/1/2* [A] | ||
1 A model: 5m/10m/20m/50m/100m/200m/500m/1* [A] | ||
*Full-scale crest factor for the maximum range of the above models is 1.5 | ||
Current Rated Ranges | 50 m / 100 m / 200 m / 500 m / 1 / 2 / 5 / 10 [V] | |
(Sensor Input) | ||
Voltage/Current | (1%~110%)*×Range | |
*Accuracy range for 1000 V voltage range and 50 A current range is (1%~100%) × Range | ||
Power Factor Accuracy Range | ±(0.001 ~ 1.000) | |
Voltage Measurement Accuracy | DC | ±(0.1%× indicating value+0.1%× range) |
0.5Hz≤f<45Hz | ±(0.1%× indicating value+0.2%× range) | |
45Hz≤f≤66Hz | ±(0.1%× indicating value+0.1%× range) | |
66Hz<f≤1kHz | ±(0.1%× indicating value+0.2%× range) | |
1kHz<f≤10kHz | ±({0.1+0.05×(f-1)}%× indicating value+0.2%× range) | |
10kHz<f≤100kHz | ±({0.5+0.04×(f-10)}%× indicating value+0.3%× range) | |
Current Measurement Accuracy | DC | ±(0.1%× indicating value+0.1%× range) |
0.5Hz≤f<45Hz | ±(0.1%× indicating value+0.2%× range) | |
45Hz≤f≤66Hz | ±(0.1%× indicating value+0.1%× range) | |
66Hz<f≤1kHz | ±(0.1%× indicating value+0.2%× range) | |
1kHz<f≤10kHz | ±((0.1×f)% indicating value+0.2%× range) | |
10kHz<f≤100kHz | ±({1+0.08×(f-10)}%×indicating value+0.3%× range) | |
Active Power Measurement Accuracy | DC | ±(0.1%× indicating value+0.1%× range) |
0.5Hz≤f<45Hz | ±(0.3%× indicating value+0.2%× range) | |
45Hz≤f≤66Hz | ±(0.1%× indicating value+0.1%× range) | |
66Hz<f≤1kHz | ±(0.2%× indicating value+0.2%× range) | |
1kHz<f≤10kHz | ±({0.2+0.1×(f-1)}%× indicating value+0.2%× range) | |
10kHz<f≤50kHz | ±({0.2+0.1×(f-1)}%× indicating value+0.3%× range) | |
50kHz<f≤100kHz | ±({5.1+0.18×(f-50)}%× indicating value+0.3%× range) | |
Active Power Measurement Range | 50 A model:11mW~11kW@220V,PF=0.01~1 | |
Optional: | ||
20 A model:2.2mW~4.4kW@220V,PF=0.01~1 | ||
10 A model:1.1mW~2.2kW@220V,PF=0.01~1 | ||
5 A model:0.4mW~1.1kW@220V,PF=0.01~1 | ||
2 A model:0.2mW~440W@220V,PF=0.01~1 | ||
1 A model:0.1mW~220W@220V,PF=0.01~1 | ||
Low Power Factor | Apparent power accuracy,±(0.2%×indicating value)@PF=0 | |
Power Accuracy Range | Active power accuracy: add 0.05%@PF=0.001~0.1 | |
Active Power Maximum Resolution | 0.1mW | |
Frequency Measurement Range | DC,0.5Hz ~ 100kHz | |
Frequency Measurement Accuracy | ±0.1%× indicating value | |
Harmonic Measurement | 10Hz ~ 600Hz, 1st ~ 50th harmonic content, total distortion | |
Energy Measurement Range | 0 ~ 999999 MWh (Resolution: 1 mWh / 0.01 mAh) | |
Energy Measurement Accuracy | ±0.2%× indicating value | |
Expanded Uncertainty | Voltage, current, power, frequency, energy ≤ 0.20% | |
Filter Function | 500 Hz, 5.5 kHz voltage-line, current-line and frequency filtering | |
Transformation Ratio Range | Voltage 1 ~ 50000, Current 0.1 ~ 5000.0, BNC 0.01 ~ 999.99 | |
Data Update Cycle | 100m / 250m / 500m / 5[s] | |
Alarm Functions | Voltage, current, power, power factor; upper limit, lower limit, threshold setting | |
Control Interfaces | Standard: RS-232, Digital I/O Interface; | |
Display | 7-inch widescreen color LCD touchscreen | |
Overall Dimensions(W×H×D) | 213 (W, excluding mounting ears) × 132.5 (H, excluding feet) × 483.5 (D, excluding terminals) mm | |
Foot Height | 14.5 mm | |
Terminal Depth | 32.5 mm (current terminals) | |
Net Weight | Approx. 7 kg | |
* Due to layout limitations, only best‑selling models are shown.Contact us for a complete product selection.