The BSC69 Series is a compact high-power regenerative DC electronic load. It simulates various load characteristics and feeds regenerated energy back to the grid with zero pollution. It helps users save electricity and thermal dissipation costs while meeting energy-saving and environmental-protection requirements. Adopting a modular high-power-density design, it achieves power absorption up to 18 kW within a 3U form factor.
| Model | Voltage | Current | Power | Accuracy | Interface | Size | Inquiry |
|---|---|---|---|---|---|---|---|
| BSC69100-170 | 100V | 170A | 5kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69100-340 | 100V | 340A | 10kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69100-510 | 100V | 510A | 15kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69300-75 | 300V | 75A | 6kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69300-150 | 300V | 150A | 12kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69300-225 | 300V | 225A | 18kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69500-40 | 500V | 40A | 6kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69500-80 | 500V | 80A | 12kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69500-120 | 500V | 120A | 18kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69800-25 | 800V | 25A | 6kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69800-50 | 800V | 50A | 12kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC69800-75 | 800V | 75A | 18kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC691000-15 | 1000V | 15A | 10kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC691000-30 | 1000V | 30A | 12kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC691000-45 | 1000V | 45A | 18kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC691500-25 | 1500V | 25A | 12kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC691500-40 | 1500V | 40A | 18kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| BSC692250-25 | 2250V | 25A | 18kW |
≤±(0.05%+0.04%FS)/≤±(0.1%+0.1%FS) |
RS232/RS485/CAN/ LAN |
3U | |
| No models match the selected filters | |||||||
*Specifications for the product series are subject to change without notice.
• Feeds DC energy back to the local grid with regeneration efficiency up to 95%
• High power density: 18 kW in a 3U chassis
• Maximum DC input voltage per unit up to 2250 V
• Maximum DC input current per unit up to 510 A
• Comprehensive protection: OVP, OCP, OPP, OTP, and reverse-connection protection for SENSE terminals
• Master-slave parallel operation with active current sharing; up to 36 identical units can be paralleled
• Integrated function generator for arbitrary waveform output
• Multiple built-in interfaces; optional communication interfaces include RS232/RS485/LAN/CAN
• Built-in remote analog control interface.
• Supports the SCPI command set.
• Equipped with a high-brightness color LCD display, featuring an elegant appearance and intuitive operation.
Energy Feedback, Energy Conservation and Emission Reduction
A key feature of the BSC69 Series regenerative DC electronic load is its AC input terminal, which also acts as an output to feed DC energy back to the grid, with conversion efficiency up to 95 %. This energy-conversion approach helps lower electricity costs and removes the requirement for costly cooling systems. Conventional electronic loads convert incoming DC power into heat during operation and therefore require cooling systems for heat dissipation.

Schematic Diagram of Basic Power Conversion Principle
Parallel Operation
The BSC69000 Series regenerative DC electronic load can operate standalone or in master-slave parallel mode for maximum application flexibility. Its dedicated current-sharing design ensures balanced current distribution among load modules and consistent performance. When higher power capacity is required, up to 36 identical-model units can be paralleled to build a higher-power load system. System configuration is fast and scalable. Paralleled units maintain the same performance specifications and ease-of-use as a single unit.
High Power Density
Conventional dissipative electronic loads are not only energy-intensive but also bulky and heavy. A 30 kW dissipative load typically requires at least 24U of rack space, resulting in difficult handling and higher costs. In contrast, the BSC69000 Series features a high-power-density design, delivering up to 18 kW of power absorption in a 3U chassis. For the same output power, volume is reduced by 80%.
Analog Control Interface
Isolated analog terminals are located on the rear panel. Applying a 0‑10 V or 0‑5 V signal to the analog input pins sets output voltage, current and power from 0 % to 100 % of their rated values. Analog outputs provide 0‑10 V or 0‑5 V signals proportional to 0–100% of the actual output for monitoring. In addition, several input and output pins are available for control and status monitoring of the unit.
Protection Functions
To protect connected load equipment, users can set threshold values for Over-Voltage Protection (OVP), Over-Current Protection (OCP) and Over-Power Protection (OPP).If any threshold is exceeded, the DC output will be cut off immediately, with a status signal triggered on both the display and communication interface. This series also integrates Over-Temperature Protection (OTP). In the event of overheating, the DC output is disabled to protect both the DUT and the power supply unit.
Function Generator
All models in this series feature a true function generator capable of generating typical waveforms and applying them to either output voltage or output current. The generator can be configured via the front‑panel controls or remotely over any digital communication interface. Preset functions deliver a full set of configurable parameters including Y‑offset, time, frequency and amplitude.

Sequence Testing
Besides the standard waveforms from the function generator, the unit also supports complex custom waveforms. The sequence test function provides 50 sequences stored in non‑volatile memory. Each sequence contains up to 20 test steps. Users may edit parameters for each step as needed. The power supply can run sequential outputs under constant‑voltage, constant‑current or constant‑power modes to meet specific test requirements.
Sequence Test Example
A typical aging‑test procedure follows this pattern: output voltage rises at a defined slew rate and is held for a set duration, steps up to another voltage level with additional incremental steps and hold periods, and finally ramps down to zero. In some cases, cyclic voltage switching sequence tests are also required. An example voltage waveform for aging testing is shown in the figure below.

Model | BSC69100-170 | BSC69100-340 | BSC69100-510 | BSC69300-75 | BSC69300-150 | BSC69300-225 | |
AC Input | Phase | 3-phase 3-wire + PE | |||||
Voltage | 342VAC~528 VAC | ||||||
Frequency | 45~66Hz | ||||||
DC Input | Voltage | 0~100V | 0~300V | ||||
Current | 0 ~170A | 0 ~340A | 0 ~510A | 0~75A | 0~150A | 0~225A | |
Power | 0~5kW | 0 ~10kW | 0 ~15kW | 0 ~6kW | 0 ~12kW | 0 ~18kW | |
Programming Accuracy | Voltage | ≤±(0.05%+0.04%FS) | |||||
Current | ≤±(0.1%+0.1%FS) | ||||||
Power | ≤±0.8%FS | ||||||
Readback Accuracy | Voltage | ≤±(0.05%+0.04%FS) | |||||
Current | ≤±(0.1%+0.1%FS) | ||||||
Power | ≤±0.8%FS | ||||||
Ripple & Noise | RMS | 15mVrms | 40mVrms | ||||
(20Hz-300kHz) | |||||||
P-P | 200mVpp | 200mVpp | |||||
(20Hz-20MHz) | |||||||
Analog Interface | Specifications | Built-in 15-pin D-Sub female connector, electrically isolated | |||||
Signal Range | 0~5V or 0~10V (switchable) | ||||||
U / I / P Accuracy | 0~10V: ≤0.2%FS | ||||||
Protection Functions | OTP ,OVP ,OCP ,OPP ,PF | ||||||
Communication Interfaces | Communication interfaces: RS232, RS485, CAN, LAN, and more. | ||||||
Parallel Operation | Capable of paralleling up to 36 units via a true master-slave configuration over a shared bus. | ||||||
Operating Environment | Operating Temperature: 0~50°C, Humidity: <80%, non-condensing;Storage Temperature: -20~70°C, Altitude: <2000m | ||||||
Isolation Withstand Voltage | 1000VDC(Output to Earth Ground) | ||||||
Dimensions (W×D×H, mm) | 482mm×670mm×132mm | ||||||
Weight | 25kg | 35kg | 45kg | 25kg | 35kg | 45kg | |
Model | BSC69500-40 | BSC69500-80 | BSC69500-120 | BSC69800-25 | BSC69800-50 | BSC69800-75 | |
AC Input | Phase | 3-phase 3-wire + PE | |||||
Voltage | 342VAC~528 VAC | ||||||
Frequency | 45~66Hz | ||||||
DC Input | Voltage | 0~500V | 0~800V | ||||
Current | 0~40A | 0~80A | 0~120A | 0~25A | 0~50A | 0~75A | |
Power | 0 ~6kW | 0 ~12kW | 0 ~18kW | 0 ~6kW | 0 ~12kW | 0 ~18kW | |
Programming Accuracy | Voltage | ≤±(0.05%+0.04%FS) | |||||
Current | ≤±(0.1%+0.1%FS) | ||||||
Power | ≤±0.8%FS | ||||||
Readback Accuracy | Voltage | ≤±(0.05%+0.04%FS) | |||||
Current | ≤±(0.1%+0.1%FS) | ||||||
Power | ≤±0.8%FS | ||||||
Ripple & Noise | RMS | 50mVrms | 75mVrms | ||||
(20Hz-300kHz) | |||||||
P-P | 350mVpp | 550mVpp | |||||
(20Hz-20MHz) | |||||||
Analog Interface | Specifications | Built-in 15-pin D-Sub female connector, electrically isolated | |||||
Signal Range | 0~5V or 0~10V (switchable) | ||||||
U / I / P Accuracy | 0~10V: ≤0.2%FS | ||||||
Protection Functions | OTP ,OVP ,OCP ,OPP ,PF | ||||||
Communication Interfaces | Communication interfaces: RS232, RS485, CAN, LAN, and more. | ||||||
Parallel Operation | Capable of paralleling up to 36 units via a true master-slave configuration over a shared bus. | ||||||
Operating Environment | Operating Temperature: 0~50°C, Humidity: <80%, non-condensing;Storage Temperature: -20~70°C, Altitude: <2000m | ||||||
Isolation Withstand Voltage | 1000VDC(Output to Earth Ground) | ||||||
Dimensions (W×D×H, mm) | 482mm×670mm×132mm | ||||||
Weight | 25kg | 35kg | 45kg | 25kg | 35kg | 45kg | |
Model | BSC691000-15 | BSC691000-30 | BSC691000-45 | BSC691500-25 | BSC691500-40 | BSC692250-25 | |
AC Input | Phase | 3-phase 3-wire + PE | |||||
Voltage | 342VAC~528 VAC | ||||||
Frequency | 45~66Hz | ||||||
DC Input | Voltage | 0~1000V | 0~1000V | 0~1000V | 0~1500V | 0~1500V | 0~2250V |
Current | 0~15A | 0~30A | 0~45A | 0~25A | 0~40A | 0~25A | |
Power | 0~10kW | 0 ~12kW | 0 ~18kW | 0 ~12kW | 0 ~18kW | 0 ~18kW | |
Programming Accuracy | Voltage | ≤±(0.05%+0.04%FS) | |||||
Current | ≤±(0.1%+0.1%FS) | ||||||
Power | ≤±0.8%FS | ||||||
Readback Accuracy | Voltage | ≤±(0.05%+0.04%FS) | |||||
Current | ≤±(0.1%+0.1%FS) | ||||||
Power | ≤±0.8%FS | ||||||
Ripple & Noise | RMS | 100mVrms | 150mVrms | 225mVrms | |||
(20Hz-300kHz) | |||||||
P-P | 850mVpp | 1100mVrms | 1650mVrms | ||||
(20Hz-20MHz) | |||||||
Analog Interface | Specifications | Built-in 15-pin D-Sub female connector, electrically isolated | |||||
Signal Range | 0~5V or 0~10V (switchable) | ||||||
U / I / P Accuracy | 0~10V: ≤0.2%FS | ||||||
Protection Functions | OTP ,OVP ,OCP ,OPP ,PF | ||||||
Communication Interfaces | Communication interfaces: RS232, RS485, CAN, LAN, and more. | ||||||
Parallel Operation | Capable of paralleling up to 36 units via a true master-slave configuration over a shared bus. | ||||||
Operating Environment | Operating Temperature: 0~50°C, Humidity: <80%, non-condensing;Storage Temperature: -20~70°C, Altitude: <2000m | ||||||
Isolation Withstand Voltage | 1000VDC(Output to Earth Ground) | ||||||
Dimensions (W×D×H, mm) | 482mm×670mm×132mm | ||||||
Weight | 25kg | 35kg | 45kg | 35kg | 45kg | 45kg | |