The BSC66 Series is a wide-range, high-power-density DC power supply. The 2U full-width unit delivers up to 3600 W. It supports flexible operation for benchtop use and test system integration. With a 10–2000 V output range, it features thirteen voltage levels to suit various test applications. Featuring high-speed dynamic response, high-precision output and measurement, and built-in test functions, it enables users to conduct accurate, reliable, straightforward, and efficient tests.
| Model | Voltage | Current | Power | Accuracy | Interface | Size | Inquiry |
|---|---|---|---|---|---|---|---|
| BSC6610-250 | 10V | 250A | 1.5kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC6610-500 | 10V | 500A | 3kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66200-160 | 20V | 160A | 1.5kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66200-320 | 20V | 320A | 3kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC6640-60 | 40V | 60A | 800W |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC6640-100 | 40V | 100A | 1.5kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC6640-200 | 40V | 200A | 3kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC6660-75 | 60V | 75A | 1.8kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC6660-150 | 60V | 150A | 3.6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC6680-30 | 80V | 30A | 800W |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC6680-60 | 80V | 60A | 1.8kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC6680-120 | 80V | 120A | 3.6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC6680-170 | 80V | 170A | 3.6kW | ≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) | RS232/LAN/ RS485/USB | 2U | |
| BSC66100-50 | 100V | 50A | 1.8kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66100-100 | 100V | 100A | 3.6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66200-12.5 | 200V | 12.5A | 800W |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66200-25 | 200V | 25A | 1.8kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66200-50 | 200V | 50A | 3.6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66200-100 | 200V | 100A | 3.6kW | ≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) | RS232/LAN/ RS485/USB | 2U | |
| BSC66360-7.5 | 360V | 7.5A | 800W |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66360-15 | 360V | 15A | 1.8kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66360-30 | 360V | 30A | 3.6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66500-5 | 500V | 5A | 800W |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66500-10 | 500V | 10A | 1.8kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66500-20 | 500V | 20A | 3.6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66750-3.5 | 750V | 3.5A | 800W |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66750-7 | 750V | 7A | 1.8kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC66750-14 | 750V | 14A | 3.6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC661000-2.5 | 1000V | 5A | 1.8kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC661000-5 | 1000V | 5A | 1.8kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSC661000-10 | 1000V | 10A | 3.6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| BSV662000-6 | 2000V | 6A | 3.6kW |
≤±(0.03%+0.02%FS)/≤±(0.05%+0.05%FS) |
RS232/LAN/ RS485/USB |
2U | |
| No models match the selected filters | |||||||
*Specifications for the product series are subject to change without notice.
• Adjustable output voltage and current slew rates.
• Offers wide‑range output capability, with its output range 3 times greater than matrix power supplies of an identical power rating.
• Utilizes a high‑frequency LLC multi‑resonant inverter, achieving overall unit efficiency of up to 93%.
• Master-slave mode supports parallel operation with active current sharing; multiple units can be paralleled.
• Features built‑in OVP, OCP, OPP and OTP protection, as well as reverse‑connection protection for SENSE terminals.
• Features remote‑sense terminals for lead‑voltage‑drop compensation during high‑current operation.
• Comes with an integrated discharge circuit (Uout < 10 V within 1 s).
• Equipped with multiple communication interfaces, including RS232, RS485, LAN and CAN.
• High-brightness color LCD display; intuitive and straightforward operation with an elegant design.
PV Simulation Function
Power Supply Interface

Model | BSC6610-250 | BSC6610-500 | BSC6620-160 | BSC6620-320 | BSC6640-60 | BSC6640-100 | BSC6640-200 | |
AC Input | Phase | 1ph+N+PE | ||||||
Voltage | 220VAC±10% | |||||||
Frequency | 45~66Hz | |||||||
Power Factor | ≥0.99 | |||||||
DC Output | Voltage | 0~10V | 0~20V | 0~40V | ||||
Current | 0~250A | 0~500A | 0~160A | 0~320A | 0~60A | 0~100A | 0~200A | |
Power | 0~1.8kW | 0~3.6kW | 0~1.8kW | 0~3.6kW | 0~800W | 0~1.8kW | 0~3.6kW | |
Efficiency | ≤92% | ≤93% | ||||||
Programming Accuracy | Voltage | ≤±(0.03%+0.02%FS) | ||||||
Current | ≤±(0.05%+0.05%FS) | |||||||
Power | ≤±0.4%FS | |||||||
Readback Accuracy | Voltage | ≤±(0.03%+0.02%FS) | ||||||
Current | ≤±(0.05%+0.05%FS) | |||||||
Power | ≤±0.4%FS | |||||||
Ripple & Noise | RMS | 10mVrms | ||||||
(20Hz-300kHz) | ||||||||
P-P | 100mVpp | |||||||
(20Hz-20MHz) | ||||||||
Source Effect | Voltage | ≤0.02%FS (±10%ΔUACInput) | ||||||
Current | ≤0.05%FS (±10%ΔUACInput) | |||||||
Load Effect | Voltage | ≤0.05%FS(0-100% Load Regulation) | ||||||
Current | ≤0.15%FS(0-100%ΔUDC Load Regulation) | |||||||
Analog Interface (Optional) | Specifications | Builtin 15pin DSub female connector, electrically isolated | ||||||
Signal Range | 0~5V or 0~10V (switchable) | |||||||
U / I / P Accuracy | 0~10V: ≤0.2%FS | |||||||
Dynamic Response Time | LoadRegulating Settling Time | ≤2ms(Load change: 10100%) | ||||||
Output Voltage Rise Time | ≤10 ms (10–90% of full scale) | |||||||
Protection Functions | OTP ,OVP ,OCP ,OPP ,PF | |||||||
Communication Interfaces | Standard: RS232 + LAN Optional: RS485, USB | |||||||
Operating Environment | Operating Temperature: 0~50°C, Humidity: <80%, noncondensing;Storage Temperature: 20~70°C, Altitude: <2000m | |||||||
Isolation Withstand Voltage | 1000VDC(Output to Earth Ground) | |||||||
Dimensions (W×D×H, mm) | 482×530×88 | 482×455×88mm 2U Standard Chassis | 482×480×88mm 2U Standard Chassis | |||||
Packaging Dimensions (W×D×H, mm) | 668×665×220 | |||||||
Weight /Gross Weight | 11.5kg/15.3kg | 14.8kg/18.8kg | 11.5kg/15.3kg | 14.8kg/18.8kg | 9.6kg/13.5kg | 10.8kg/14.6kg | 11.5kg/15.3kg | |
Model | BSC6660-75 | BSC6660-150 | BSC6680-30 | BSC6680-60 | BSC6680-120 | BSC66100-50 | BSC66100-100 | BSC66200-12.5 | BSC66200-25 | BSC66200-50 | |
AC Input | Phase | 1ph+N+PE | |||||||||
Voltage | 220VAC±10% | ||||||||||
Frequency | 45~66Hz | ||||||||||
Power Factor | ≥0.99 | ||||||||||
DC Output | Voltage | 0~60V | 0~80V | 0~100V | 0~200V | ||||||
Current | 0~75A | 0~150A | 0~30A | 0~60A | 0~120A | 0~50A | 0~100A | 0~12.5A | 0~25A | 0~50A | |
Power | 0~1.8kW | 0~3.6kW | 0~800W | 0~1.8kW | 0~3.6kW | 0~1.8kW | 0~3.6kW | 0~800W | 0~1.8kW | 0~3.6kW | |
Efficiency | ≤92% | ≤93% | |||||||||
Programming Accuracy | Voltage | ≤±(0.03%+0.02%FS) | |||||||||
Current | ≤±(0.05%+0.05%FS) | ||||||||||
Power | ≤±0.4%FS | ||||||||||
Readback Accuracy | Voltage | ≤±(0.03%+0.02%FS) | |||||||||
Current | ≤±(0.05%+0.05%FS) | ||||||||||
Power | ≤±0.4%FS | ||||||||||
Ripple & Noise | RMS | 10mVrms | 20mVrms | ||||||||
(20Hz-300kHz) | |||||||||||
P-P | 100mVpp | 175mVpp | |||||||||
(20Hz-20MHz) | |||||||||||
Source Effect | Voltage | ≤0.02%FS (±10%ΔUACInput) | |||||||||
Current | ≤0.05%FS (±10%ΔUACInput) | ||||||||||
Load Effect | Voltage | ≤0.05%FS(0-100% Load Regulation) | |||||||||
Current | ≤0.1%FS(0-100%ΔUDC Load Regulation) | ||||||||||
Analog Interface (Optional) | Specifications | Built-in 15-pin D-Sub female connector, electrically isolated | |||||||||
Signal Range | 0~5V or 0~10V (switchable) | ||||||||||
U / I / P Accuracy | 0~10V: ≤0.2%FS | ||||||||||
Dynamic Response Time | LoadRegulating Settling Time | ≤2ms(Load change: 10-100%) | |||||||||
Output Voltage Rise Time | ≤10 ms (10–90% of full scale) | ||||||||||
Protection Functions | OTP ,OVP ,OCP ,OPP ,PF | ||||||||||
Communication Interfaces | Standard: RS232 + LAN Optional: RS485, USB | ||||||||||
Operating Environment | Operating Temperature: 0~50°C, Humidity: <80%, non-condensing;Storage Temperature: -20~70°C, Altitude: <2000m | ||||||||||
Isolation Withstand Voltage | 1000VDC(Output to Earth Ground) | 1000VDC(Output to Earth Ground) | |||||||||
Dimensions (W×D×H, mm) | 482×455×88 2U Standard Chassis | ||||||||||
Packaging Dimensions (W×D×H, mm) | 668×665×220 | ||||||||||
Weight /Gross Weight | 10.8kg/14.6kg | 13.5kg/17.5kg | 9.6kg/13.5kg | 10.8kg/14.6kg | 13.5kg/17.5kg | 10.8kg/14.6kg | 13.5kg/17.5kg | 9.6kg/13.5kg | 10.8kg/14.6kg | 13.5kg/17.5kg | |
Model | BSC66360-7.5 | BSC66360-15 | BSC66360-30 | BSC66500-5 | BSC66500-10 | BSC66500-20 | BSC66750-3.5 | BSC66750-7 | BSC66750-14 | BSC661000-2.5 | BSC661000-5 | BSC661000-10 | BSC662000-6 | |
AC Input | Phase | 1ph+N+PE | ||||||||||||
Voltage | 220VAC±10% | |||||||||||||
Frequency | 45~66Hz | |||||||||||||
Power Factor | ≥0.99 | |||||||||||||
DC Output | Voltage | 0~360V | 0~500V | 0~750V | 0~1000V | 0~1000V | 0~1000V | 0~2000V | ||||||
Current | 0~7.5A | 0~15A | 0~30A | 0~5A | 0~10A | 0~20A | 0~3.5A | 0~7A | 0~14A | 0~2.5A | 0~5A | 0~10A | 0~6A | |
Power | 0~800W | 0~1.8kW | 0~3.6kW | 0~800W | 0~1.8kW | 0~3.6KW | 0~800W | 0~1.8kW | 0~3.6KW | 0~800W | 0~1.8kW | 0~3.6kW | 0~3.6kW | |
Efficiency | ≤93% | |||||||||||||
Programming Accuracy | Voltage | ≤±(0.03%+0.02%FS) | ||||||||||||
Current | ≤±(0.05%+0.05%FS) | |||||||||||||
Power | ≤±0.4%FS | |||||||||||||
Readback Accuracy | Voltage | ≤±(0.03%+0.02%FS) | ||||||||||||
Current | ≤±(0.05%+0.05%FS) | |||||||||||||
Power | ≤±0.4%FS | |||||||||||||
Ripple & Noise | RMS | 40mVrms | 50mVrms | 100mVrms | 150mVrms | |||||||||
(20Hz-300kHz) | ||||||||||||||
P-P | 250mVpp | 325mVpp | 650mVpp | 800mVpp | ||||||||||
(20Hz-20MHz) | ||||||||||||||
Source Effect | Voltage | ≤0.02%FS (±10%ΔUACInput) | ||||||||||||
Current | ≤0.05%FS (±10%ΔUACInput) | |||||||||||||
Load Effect | Voltage | ≤0.05%FS(0-100% Load Regulation) | ||||||||||||
Current | ≤0.1%FS(0-100%ΔUDC Load Regulation) | |||||||||||||
Analog Interface (Optional) | Specifications | Built-in 15-pin D-Sub female connector, electrically isolated | ||||||||||||
Signal Range | 0~5V or 0~10V (switchable) | |||||||||||||
U / I / P Accuracy | 0~10V: ≤0.2%FS 0~5V: ≤0.4%FS | |||||||||||||
Dynamic Response Time | Load-Regulating Settling Time | ≤2ms(Load change: 10-100%) | ||||||||||||
Output Voltage Rise Time | ≤10 ms (10–90% of full scale) | |||||||||||||
Protection Functions | OTP ,OVP ,OCP ,OPP ,PF | |||||||||||||
Communication Interfaces | Standard: RS232 + LAN Optional: RS485, USB | |||||||||||||
Operating Environment | Operating Temperature: 0~50°C, Humidity: <80%, non-condensing;Storage Temperature:-20~70°C, Altitude: <2000m | |||||||||||||
Isolation Withstand Voltage | 1000VDC(Output to Earth Ground) | |||||||||||||
Dimensions (W×D×H, mm) | 482×455×88 2U Standard Chassis | |||||||||||||
Packaging Dimensions (W×D×H, mm) | 668×665×220 | |||||||||||||
Weight /Gross Weight | 9.6kg/13.5kg | 10.8kg/14.6kg | 13.5kg/17.5kg | 9.6kg/13.5kg | 13.5kg/17.5kg | 13.5kg/17.5kg | 9.6kg/13.5kg | 10.8kg/14.6kg | 13.5kg/17.5kg | 9.6kg/13.5kg | 10.8kg/14.6kg | 13.5kg/17.5kg | 13.5kg/17.5kg | |
* Due to layout limitations, only best‑selling models are shown.Contact us for a complete product selection.