The BSC89 Series High-Power Programmable DC Electronic Load is a newly launched high‑power DC electronic load. It offers three voltage‑range options: 150 V, 600 V and 1200 V, with power ranging from 600 W to 60 kW. Equipped with a new‑generation digital controller, it supports five basic operating modes and seven advanced modes. It also offers sequence‑programming capability for user‑defined programming and automated‑test requirements.
| Model | Voltage | Current | Power | Accuracy | Interface | Size | Inquiry |
|---|---|---|---|---|---|---|---|
| BSC89006-150-60 | 150V | 60A | 600W |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89013-150-130 | 150V | 130A | 1.3kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89026-150-260 | 150V | 260A | 2.6kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89003-150-300 | 150V | 300A | 3kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89004-150-400 | 150V | 400A | 4kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89005-150-500 | 150V | 500A | 5kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89006-150-600 | 150V | 600A | 6KW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89008-150-800 | 150V | 800A | 8kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89010-150-1000 | 150V | 1000A | 10kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89012-150-1200 | 150V | 1200A | 12kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89015-150-1500 | 150V | 1500A | 15kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89018-150-1800 | 150V | 1800A | 18kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89020-150-2000 | 150V | 2000A | 20kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89025-150-2400 | 150V | 2400A | 25kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
12U | |
| BSC89030-150-2400 | 150V | 2400A | 30kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
12U | |
| BSC89035-150-2400 | 150V | 2400A | 35kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
16U | |
| BSC89040-150-2400 | 150V | 2400A | 40kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
16U | |
| BSC89045-150-2400 | 150V | 2400A | 45kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
20U | |
| BSC89050-150-2400 | 150V | 2400A | 50kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
20U | |
| BSC89060-150-2400 | 150V | 2400A | 60kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
24U | |
| BSC89006-600-40 | 600V | 40A | 600W |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89013-600-90 | 600V | 90A | 1.3kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89026-600-180 | 600V | 180A | 2.6kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89003-600-210 | 600V | 210A | 3kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89004-600-280 | 600V | 280A | 4kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89005-600-350 | 350A | 5kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | ||
| BSC89006-600-420 | 600V | 420A | 6KW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89008-600-560 | 600V | 560A | 8kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89010-600-700 | 600V | 700A | 10kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89012-600-840 | 600V | 840A | 12kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89015-600-1050 | 600V | 1050A | 15kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89018-600-1260 | 600V | 1260A | 18kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89020-600-1400 | 600V | 1400A | 20kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89025-600-1750 | 600V | 1750A | 25kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
12U | |
| BSC89030-600-2100 | 600V | 2100A | 30kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
12U | |
| BSC89035-600-2400 | 600V | 2400A | 35kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
16U | |
| BSC89040-600-2400 | 600V | 2400A | 40kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
16U | |
| BSC89045-600-2400 | 600V | 2400A | 45kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
20U | |
| BSC89050-600-2400 | 600V | 2400A | 50kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
20U | |
| BSC89060-600-2400 | 600V | 2400A | 60kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
24U | |
| Y632006-1200-25 | 1200V | 25A | 600W |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89013-1200-50 | 1200V | 50A | 1.3kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89026-1200-100 | 1200V | 100A | 2.6kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89003-1200-120 | 1200V | 120A | 3kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89004-1200-160 | 1200V | 160A | 4kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
2U | |
| BSC89005-1200-200 | 1200V | 200A | 5kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89006-1200-240 | 1200V | 240A | 6KW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89008-1200-320 | 1200V | 320A | 8kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89010-1200-400 | 1200V | 400A | 10kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
4U | |
| BSC89012-1200-480 | 1200V | 480A | 12kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89015-1200-600 | 1200V | 600A | 15kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89018-1200-720 | 1200V | 720A | 18kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89020-1200-800 | 1200V | 800A | 20kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
8U | |
| BSC89025-1200-1000 | 1200V | 1000A | 25kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
12U | |
| BSC89030-1200-1200 | 1200V | 1200A | 30kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
12U | |
| BSC89035-1200-1400 | 1200V | 1400A | 35kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
16U | |
| BSC89040-1200-1600 | 1200V | 1600A | 40kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
16U | |
| BSC89045-1200-1800 | 1200V | 1800A | 45kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
20U | |
| BSC89050-1200-2000 | 1200V | 2000A | 50kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
20U | |
| BSC89060-1200-2400 | 1200V | 2400A | 60kW |
0.025%+0.025%F.S./0.05%+0.05%F.S. |
232/LAN |
24U | |
| No models match the selected filters | |||||||
*Specifications for the product series are subject to change without notice.
• Single-unit power: 600 W to 60 kW; expandable up to 600 kW via master-slave parallel operation
• High power density: 10 kW / 4U
• Precision measurement technology with accuracy of 0.025% + 0.025% F.S. for voltage, 0.05% + 0.05% F.S. for current, and 0.2% + 0.2% F.S. for power (specifications remain unchanged at high temperatures)
• Wide-range design, delivering nearly twice the current range of conventional high-power loads at equivalent power ratings
• Excellent dynamic performance; current slew rate up to 96 A/μs
• Built-in functions include constant-current (CC), constant-voltage (CV), constant-resistance (CR), constant-power (CP), short‑circuit simulation, over‑current protection test, and sequence test
• Integrated temperature sensing chip and variable speed fan control
• Comprehensive protection functions: over-current, over-voltage, over-temperature, reverse-connection, and SENSE protection
• Built-in battery mode for discharge testing with capacity integration and timing
Application Fields
• Discharge testing for power batteries, lead-acid batteries, and fuel cells
• Testing for DC charging piles, on-board chargers (OBC), and power electronics
• Industrial testing for smart manufacturing, industrial motors, and automotive electronics
• Testing for military and aerospace power supplies, high‑power switching power supplies, high‑voltage UPS, telecom power supplies, and server power supplies
• Testing for relay simulated loads, PV module arrays, and wind power virtual loads
• Testing for DC power supplies, and power electronic components
• Simulation testing for energy storage systems
|
|
|
|
On‑Board Charger (OBC) | Charging Pile | Energy Storage System (ESS) | Power Battery |
|
|
|
|
Wind Power Generation | Industrial Motor | Photovoltaic (PV) Panel | DC Power Module |
Ultra-High Power Density, Compact Size, Wide Voltage Rang
The BSC89000 Series offers a wide voltage and current input range, covering various test requirements including high current / low voltage or high voltage / low current conditions. Featuring a high power density design, it occupies half the volume and one third the weight of conventional electronic loads.

Multiple Operating Modes
The BSC89000 Series provides four basic operating modes: constant current (CC), constant voltage (CV), constant resistance (CR), and constant power (CP), covering a wide range of test requirements. It also supports combined modes including CV+CC, CR+CC, and CP+CC. Users can set a current limit according to their test requirements to prevent over current damage to the device under test (DUT).
The CV+CC mode can simulate battery charging characteristics for testing charging piles, on‑board chargers (OBC), and similar products. The CR+CC mode is suitable for power supply start-up testing, preventing over current protection triggers during power-on.

CCD Mode – Fast Dynamic
The BSC89000 Series features a high speed dynamic load function with dynamic response up to 50 kHz. Users can set a repetition count from 1 to 100 000 within a defined time period, or enable continuous dynamic loading. As shown in the figure below, high /low level load current values, load duration, and rise/fall slew rate are all configurable.

LIST Mode – Sequence Loading
The BSC89 Series includes a built in sequence test function supporting up to 8 sequence groups, each with up to 200 steps, and a step duration from 0 to 100 seconds. This mode generates various load‑current waveforms for dynamic current testing, complementing standard dynamic tests for battery discharge testing, server power supplies, and telecom power‑supply mixed‑load modulation.

High-Precision Measurement
The BSC89 Series offers three measurement ranges for both voltage and current. Taking model BSC89006-1200-240 as an example, it provides three voltage ranges – 150 V, 600 V, and 1200 V – covering low, medium, and high voltage requirements. It also features three current ranges: 24 A / 120 A / 240 A, enabling higher‑accuracy readings across various operating conditions. Equipped with high‑accuracy A/D and D/A converters, the series achieves accuracy specifications of 0.025% + 0.025% F.S. for voltage, 0.05% + 0.05% F.S. for current, and 0.2% + 0.2% F.S. for power.
Master-Slave Parallel – Flexible Power Configuration
The BSC89 Series supports master‑slave parallel operation with active current sharing. When load power demand increases, units of the same model and specification can be paralleled to expand current and power capacity. The paralleled system retains all single‑unit functions and performance specifications with no recalibration required, supporting expansion up to 600 kW. Its Ethernet‑based parallel architecture delivers improved system stability.

Battery Test Mode
The BSC89 Series features a battery test function offering three discharge modes: constant‑current (CC), constant‑resistance (CR), and constant‑power (CP). Users can configure the load via voltage threshold, cut‑off capacity, and test duration (1 s to 100 000 s) to prevent battery damage caused by over‑discharge. The unit also displays discharge capacity, voltage, and time variations throughout testing. This battery test mode also applies to supercapacitors and other comparable discharge‑test scenarios.

Accurate Power Supply Protection Point Detection
When the output current (or power) of the DUT exceeds safe limits, it can cause damage. Most power supplies therefore incorporate overcurrent (OCP) and overpower (OPP) protection, which reduces output voltage or disables output under overload conditions. The BSC89 Series supports OCP and OPP test modes for such scenarios. After setting the load current and trip voltage threshold, the load stops sinking current when the output voltage drops to or below the set threshold. The protection‑trip current (or power) value is then displayed on the screen, allowing pass/fail judgment based on the protection point.


BSC89000 Series High-Power Programmable DC Electronic Load | ||||
Model | BSC89010-150-1000 | BSC89010-600-700 | BSC89010-1200-400 | |
Voltage | 150V | 600V | 1200V | |
Current | 1000A | 700A | 400A | |
Power | 10,000W | 10,000W | 10,000W | |
Minimum Operating Voltage at Full Current | 1.8V/1200A | 14V/700A | 20V/400A | |
Constant Current (CC) Mode | Range | 100/500/1000A | 70/350/700A | 40/200/400A |
Resolution | 1/5/10mA | 0.5/2.5/5mA | 0.4/2/4mA | |
Accuracy | 0.05%+0.05%F.S. | |||
Constant Voltage (CV) Mode | Range | 16/80/150V | 80/150/600V | 150/600/1200V |
Resolution | 0.1/0.5/1mV | 0.5/1/5mV | 1/5/10mV | |
Accuracy | 0.025%+0.025%F.S. | |||
Constant Power (CP) Mode | Range | 1000/5000/10000W | ||
Resolution | 20/100/200mW | |||
Accuracy | 0.2%+0.2% F.S. | |||
Constant Resistance (CR) Mode | Range | 2.5mΩ-25Ω(16V) | 25mΩ-250Ω(80V) | 50mΩ-0.5kΩ(150V) |
Resolution | 10mA/Vsense | 5mA/Vsense | 4mA/Vsense | |
Accuracy | Vin/Rset*(0.2%)+0.2%IF.S. | |||
Current Slew Rate 【1】 | Setting Range | 1mA/us-10A/us (100A) | 0.5mA/us-2.1A/us (70A) | 0.4mA/us-1.4A/us (40A) |
5mA/us-27.5A/us(500A) | 2.5mA/us-10.5A/us(350A) | 2mA/us-7A/us (200A) 4mA/ | ||
10mA/us-55A/us (1000A) | 5mA/us-21A/us (700A) | us-14A/us (400A) | ||
Resolution | 1/5/10 mA/us | 0.5/2.5/5mA/us | 0.4/2/4mA/us | |
Other Specifications | AC Voltage | 220VAC±10%,50 ~ 60Hz | ||
Communication Interfaces | 232、LAN | |||
Temperature Specifications | Operating Temperature: 0℃ ~ 40℃; Storage Temperature: 20℃ ~ 60℃ | |||
Operating Environment | Altitude: < 2000 m | |||
Weight | 35Kg | |||
Dimensions | 482mm(W)*177.8mm(H)*783mm(D) | |||
Note 【1】:
Test conditions: the test current varies between 10 % and 90 % of the unit’s rated current.
The Y63200 series includes numerous models; only selected models are listed for reference.
* Due to layout limitations, only best‑selling models are shown.Contact us for a complete product selection.