The AC8722 is a reliable, stable, compact and lightweight AC/DC power meter featuring fast-speed measurement, DC-to-1 kHz bandwidth, and enhanced load adaptability. It comes standard with RS-232, with optional RS-485 serial-communication ports, supporting the MODBUS protocol for easy test-system automation.
| Model | Voltage | Current | Accuracy | Interface | Size | Inquiry | |
|---|---|---|---|---|---|---|---|
| AC8722 | 600V | 1 A / 20 A (AC/DC) | ±(0.1%× indicating value + 0.1% × range) | RS-232 / RS-485 / Digital I/O | 2U | ||
| No models match the selected filters | |||||||
*Specifications for the product series are subject to change without notice.
• Universal wide-range design for both AC and DC; bandwidth: DC to 1 kHz; enhanced load adaptability
• Reliable and stable performance, compact size and light weight
• High-speed measurement with a minimum data-refresh rate of 0.25 s
• Voltage and current ratio setting function for easy measurement range extension
• Audible and visual alarm for over‑limit voltage, current, and power, enabling rapid on-site identification of abnormal products
•Standard RS‑232 or optional RS‑485 serial communication ports supporting MODBUS for easy test automation
• Optional digital I/O function for remote control input and alarm signal output
Model | AC8722 |
Product Name | AC/DC Power Meter |
Measurement Channels | Single-phase |
Measurement Parameters | Voltage (U), Current (I), Active Power (P), Reactive Power (Q), Apparent Power (S), Power Factor( λ), Phase Angle (Φ), Voltage Frequency ( f), Energy (Wh), Energy Accumulation Time (Time) |
Wiring Configuration | Non-removable common-ground shorting bar between the voltage and current terminals; internal connection method only |
Input Impedance | Voltage: Approx. 2 MΩ |
Current: approx. 4 mΩ (20 A range), approx. 80 mΩ (1 A range) | |
Full-Scale Crest Factor | 1.6 |
Rated Voltage Range | 600V |
Voltage Accuracy Range | 1V~600V |
Current Rated Range | 1A/20A (AC/DC) |
Current Accuracy Range | 1mA~1A/20A |
Voltage/Current Accuracy* | ±(0.1%× indicating value + 0.1% × range) |
Active Power Measurement Range | 2.2mW(PF=0.01)~4.4kW(PF=1)@220V |
Active Power Accuracy* | ±(0.1% × indicating value + 0.1% × range) |
Power Factor Accuracy Range | ±(0.01~1) |
Frequency Measurement Range | DC,45Hz≤f≤1kHz |
Frequency Measurement Accuracy | ±(0.1%× indicating value) (voltage amplitude must exceed 10%× range) |
Active Power Resolution | 0.01W |
Power Factor Resolution | 0.001 |
Energy Measurement Range | 0~99999MWh |
Energy Measurement Accuracy | ±(0.2% × indicating value) |
Expanded Uncertainty | Voltage, current, power, frequency and energy uncertainty ≤ 0.30% |
Energy Accumulation Time | 999:59:59 |
Energy Timing Accuracy | ±(0.05%× indicating value) |
Voltage/Current Transformation Ratio | 0.1~1000.0 |
Data Update Cycle | 0.25,0.5,1[s] |
Alarm Function | 5 groups: voltage, current and power upper/lower limits and threshold settings |
Control Interfaces | RS-232 (optional RS-485), digital I/O function (optional) |
Overall Dimensions(W×H×D) | 213 mm (W, front panel) × 88 mm (H, front panel) × 386 mm (D, incl. terminals) |
Panel Cutout Dimensions | 210(W)×85(H) mm |
Foot Height | 15 mm |
Net Weight | Approx. 3 kg |
Power Consumption | Approx. 10 VA |
*[Accuracy Conditions]
Warm-up: ≥15 minutes after power-on
Ambient temperature: 23±5℃, Humidity: 30%~75%RH, Power supply: AC 100V~240V, 45~65Hz
Temperature coefficient: At 5~18℃ or 28~40℃, the error increases by ±(Reading × 0.06%) / ℃
* Due to layout limitations, only best‑selling models are shown.Contact us for a complete product selection.